Nominal Output Voltage(s) Supported | 120V |
Frequency Compatibility | 60 Hz |
Output Receptacles | (2) 5-15R; (2) 5-15/20R |
Output (Watts) | 3000 |
Continuous Output Capacity (Watts) | 3000 |
Peak Output Capacity (Watts) | 6000 |
Output Voltage Regulation | Maintains PWM sine wave output voltage of 115 VAC (+/- 8 VAC) |
Output Frequency Regulation | 60 Hz (+/- 3 Hz) |
Overload Protection | Automatic overload protection shuts down inverter system in the event of overloads. Output is protected by 2 built-in 20A circuit breakers (each controlling power to 2 outlets). Inverter and electrical system are further protected via set of 6 40A automotive input fuses. |
Recommended Electrical Service | Requires 12VDC input source capable of delivering 286A for the required duration (when used at full capacity). For automotive applications, professional hardwire installation with 500A battery system fusing is recommended. |
Maximum Input Amps / Watts | Full continuous load - 286A at 12VDC, No load - 2.6A at 12VDC, Shutdown / load sense mode - less than 500 milliamps |
Input Connection Type | DC INPUT: Set of 4 DC bolt-down terminals (2 red / 2 black). AC INPUT: hardwire |
Input Cord Length Details | User supplies cabling. Minimum gauges for full load operation: 0 (10 ft max), 00 or 2/0 (13 ft max), Twin 00 using 4 conductors (26 ft) |
Voltage Compatibility (VDC) | 12 |
DC System Voltage (VDC) | 12 |
Front Panel LEDs | Set of 6 LEDs offer continuous status information on load percentage (5 levels reported) and battery charge level (7 levels reported). See manual for sequences. |
Switches | 3 position rocker switch enables on/off power control, plus "remote" setting which enables inverter to be remotely powered on or off when used in conjunction with included module. |
Audible Alarm | Dual function alarm indicates overload conditions or low DC input voltage of 10.5V or less. |
Shipping Dimensions (hwd / in.) | 11.000 x 4.600 x 15.900 |
Shipping Weight (lbs.) | 16.6000 |
Unit Dimensions (hwd / in.) | 4 x 10.5 x 13.5 |
Unit Weight (lbs.) | 13.2 |
Cooling Method | Fan |
Material of Construction | Aluminum / sheet metal |
Form Factors Supported | Mounting slots enable permanent placement of inverter on any horizontal surface (see manual for additional mounting information) |
Relative Humidity | 0-95% non-condensing |
Load Sensing | Optional load sense function enables automatic inverter shutoff and startup as connected equipment is powered off and on. Front panel load sense potentiometer can be set to shutoff or turn on inverter power in response to loads of any level, up to 150 watts. |
TVSS Grounding | Grounding lug grounds the inverter to vehicle or earth ground - user supplies cabling |
Remote Control Capability | Yes |